Plugmold 2000 installation




















The specific type of NEMA receptacle required depends on how many receptacles will be installed on the particular small appliance branch circuit. This requires that we now look at the definition of a Receptacle in the NEC.

Article of the NEC defines the term receptacle as follows: Receptacle. A contact device installed at the outlet for the connection of an attachment plug, or for the direct connection of electrical utilization equipment designed to mate with the corresponding contact device.

A single receptacle is a single contact device with no other contact device on the same yoke. A multiple receptacle is two or more contact devices on the same yoke. In accordance with Article For a ampere circuit, this table allows either a ampere or a ampere receptacle to be used.

For help with specific part number selection, you can refer to the following articles: Plugmold series steel product selection. Plugmold AL series product selection Plugmold NM series product selection Plugmold series product selection Additional information for product selection can be found at www. Skip to Navigation Skip to Main Content. Toggle SideBar. Knowledge Base. How can we help? Content Body Title.

Plugmold - Installation of Plugmold for 20A circuits. Article Number. A multiple receptacle is two or more contact devices on the same yoke In accordance with Article TABLE Maximum Cord-and Plug Connected Load to Receptacle Circuit Rating Amperes Receptacle Rating Amperes Maximum Load Amperes 15 or 20 15 12 16 20 20 16 24 30 30 24 Based on these requirements, we can now determine the ratings of the receptacles used on the ampere small appliance branch circuits: One single receptacle : A 20A branch circuit with one single receptacle and no other receptacles must use a NEMA R receptacle.

Single and multiple receptacles: A 20A branch circuit with any combination of single and multiple receptacles can use either NEMA R or R receptacles. Connect wired section to feed. Connect feed wires to wired raceway sections. It is recommended to stagger connection points to allow room for all connections. Snap raceway cover onto base. If necessary, snap receptacle harness into cover making sure to line up receptacle faces with pre-punched holes in the raceway cover. Engage lower edge of cover over the edge of the base.

Starting at one end and progressing along the unit, snap in upper edge. Ensure that wires are pushed completely into the base before assembling the cover to. Snap on cover clip to cover joint seams where lengths of covers come together. To remove cover, insert removal tool into groove, push down and twist. Electrical Code or codes administered by local authorities.

Laboratory NRTL and should be installed in conformance with current. Previous Page. Next Page. Twist out KOs in cover section where raceway enters. This manual is also suitable for: Plugmold tr aluminum. Print page 1 Print document 4 pages.

Rename the bookmark. Delete bookmark? Cancel Delete. Delete from my manuals? Sign In OR.